CoolTeg Plus XC

CoolTeg Plus XC

CoolTeg Plus XC in-row units are based on the direct expansion principal. A compressor is integrated into the indoor unit, which is connected to its outdoor condenser, the distance between the indoor and outdoor units being up to 60m. This arrangement protects all important components from climatic conditions (heat, frost, rain, snow, sand storm) and allows cooling to be run independently of ambient conditions, which can range from -40 °C to +55 °C.

 

CoolTeg Plus XC30

This unique cooling unit with a width of only 30 cm and a maximum  power of up to 22 kW has a twin rotary compressor and a BLDC control that provides continuous cooling performance from 10 to 100%.This extraordinary universal unit is particularly suited to smaller data centers or wherever strong and powerful cooling units would be over-dimensioned in performance and cost.

sizeOnly 30 cm wide

coolFluent cooling capacity control of 10% to 100%

speedMaximum capacity up to 22 kW

 

CoolTeg Plus XC40

This cooling unit has a power output of up to 42 kW at a width of 40 cm. At present, the most efficient inverter-controlled compressor is built-in indoor unit with an electronically controlled expansion valve and advanced control logic. The cooling capacity can be provided in the range of 20% - 100%. This powerful cooling unit is suitable for large data centers and wherever strong cooling performance is required.

size40 cm wide

coolCooling performance from 20% to 100 %

speedMaximum capacity up to 42 kW

Where to buy
Print Favorities E-mail Twitter RSS
  • CoolTeg-Plus-XC_AC-TXC-42-30-main-WEB.jpgCoolTeg-Plus-XC_AC-TXC-42-30-front-right-WEB.jpgCoolTeg-Plus-XC_AC-TXC-42-30-left-front-WEB.jpgCoolTeg-Plus-XC_AC-TXC-42-30-right-back-WEB.jpg

CoolTeg Plus XC30

MAIN ADVANTAGES:

  • Cooling capacity of up to 22 kW
  • Operation temperatures from -40 up to +55 °C
  • Fluent cooling capacity control of 10% - 100 %
  • For safety reasons compressor positioned inside data center
  • Low noise of outdoor unit
  • Refrigerant R410A

 DESCRIPTION:

  • Twin rotary compressor
  • BLDC driven compressor
  • Electronic expansion valve and advanced steering logic
  • Low vibrations
  • Low- and high-pressure safety switches
  • Refrigerant valves for easy maintenance
  • Distance between indoor and outdoor unit up to 60 m

Outdoor unit

Internal in-row cooling unit CoolTeg Plus XC30 is compatitable with any outdoor condenser with variable airflow. Outdoor unit for heat rejection should be designed based on the condensing temperature of the refrigerant, plus typical max. regional ambient temperatures. Local conditions determine what type and size of outdoor condenser can be deployed.

CoolTeg Plus XC 30
Indoor unit type Unit AC-TXC-42-30/XX-XXX
Connected outdoor unit   AC-CONDX-xx-xx
BASIC DATA
Cooling system Direct expansion
Architecture1 Open or closed
Nominal cooling capacity2 kW 21,5
Nominal net cooling capacity3 kW 20,7
Power supply V/f/Hz 400/3/50-60
Fan power consumption (maximum kW 0,85
Compressor power consumption4 kW 5,45
Nominal airflow5
m3/h 4000
Number of radial fans pcs 5
Motor fan technologyy EC
Refrigerant type R410A
Filter class6 G4
DIMENSIONS
Height mm (U) 1978 (42U), 2111 (45U), 2245 (48U)
Width mm 300
Depth7 mm 1000 or 1200
Weight - depth 1000 mm, výška 42/45/48U kg 194/199/204
Weight - depth 1200 mm, výška 42/45/48U kg 204/209/214
CONNECTION DIMENSIONS
Piping diameter - liquid line mm 12
Piping diameter - gas line mm 16

1
CoolTeg Plus units can be used either independently (in rack rows), or integrated in a Modular Closed Loop (MCL)—closed architecture rack systems and cooling units. Indoor unit type is changed as per ordering matrix.
Cooling capacity is changed by controller. Nominal cooling capacity is calculated at indoor hot air temperature 35 °C without condensation (heat-exchanger‘s temperature above dew-point), outdoor temp. +35 °C, clean fi lters.
Net cooling capacity is the total cooling capacity reduced for fan heat load. Useful unit cooling capacity.
Power consumption at condensing temperature 45 °C and evaporation temperature 10 °C
5Airfl ow is automatically changed by controller. Nominal airfl ow matches nominal cooling capacity.
Units in Modular Closed Loop architecture (MCL) are delivered without fi lters (standard).
Units in Modular Closed Loop architecture (MCL) are available in 1 200 mm depth only.

CoolTeg Plus XC40

MAIN ADVANTAGES:

  • Cooling capacity up to 42 kW 
  • Operation temperatures from -40 up to +55 °C 
  • Very high energy efficiency and stepless capacity control
  • Keeps datacenter free of water
  • Compressor safely positioned inside data center
  • Low noise of outdoor unit
  • Perfect oil management for piping system
  • Refrigerant R410A

DESCRIPTION:

  • The most efficient compressor to date
  • Inverter-driven compressor built into internal unit
  • Environmentally-friendly refrigerant R410a Electronic expansion valve and advanced steering logic
  • Stepless capacity control from 20 to 100 %
  • Oil separator and Trax-oil inside
  • Low- and high-pressure safety switches
  • Refrigerant valves for easy maintenance
  • Operation in outdoor temperatures between -40 °C and +55 °C
  • Distance between indoor and outdoor unit up to 60 m

Outdoor unit

Internal in-row cooling unit CoolTeg Plus XC is compatitable with any outdoor condenser with variable airflow. Outdoor unit for heat rejection should be designed based on the condensing temperature of the refrigerant, plus typical max. regional ambient temperatures. Local conditions determine what type and size of outdoor condenser can be deployed.

 

CoolTeg Plus XC 40
Indoor unit type Unit AC-TXC-42-40/XX-XXX
Connected outdoor unit   AC-COND2-xx-xx
BASIC DATA
Cooling system Direct expansion
Architecture1 Open and closed
Nominal cooling capacity2 kW 42.2
Nominal net cooling capacity 3 kW 39.1
Power supply V/f/Hz 400/3/50-60
Running current A 22.7
Maximum current A 25.3
Fan power consumption (maximum) kW 3.1
Compressor power consumption (maximum) kW 12.3
Nominal airflow4 m3/h 9000
Number of radial fans pcs 3
Motor fan technology EC
Refrigerant type R410A
Filter class5 G4
DIMENSION
Height mm (U) 1978 (42U), 2111 (45U), 2245 (48U)
Width mm 400
Depth6 mm 1000 nebo 1200
Weight – depth 1000 mm, výška 42/45/48U kg 262/270/278
Weight – depth 1200 mm, výška 42/45/48U kg 274/284/294
CONNECTION DIMENSION
Piping diameter - liquid line mm 16
Piping diameter - gas line mm 22

1
CoolTeg Plus units can be used either independently (in rack rows), or integrated in a Modular Closed Loop(MCL) – closed architecture rack systems and cooling units. Indoor unit type is changed as per orderingmatrix.
2 Cooling capacity is changed by controller. Nominal cooling capacity is calculated at indoor hot airtemperature 35 °C without condensation (air humidity below dew-point), outdoor temp. +35 °C, clean filters.
3 Net cooling capacity is the total cooling capacity reduced for fan heat load. Useful unit cooling capacity.
4 Airflow is automatically changed by controller. Nominal airflow matches nominal cooling capacity.
5 Units in Modular Closed Loop architecture (MCL) are delivered without filters as standard6 Units in Modular Closed Loop architecture (MCL) are available in 1200 mm depth only
6 Units in Modular Closed Loop architecture (MCL) are available in 1200 mm depth only